Arteriosclerosis Detector MAD-701

Arteriosclerosis Detector MAD-701 supports a wide blood pressure measurement range from 0 to 260 mmHg and a pulse rate range of 40 to 199 BPM. It uses oscillography blood pressure measurement and synchronized limb pressurization for simultaneous four-limb testing. With four pressure modules and durable cuffs supporting 8,000 cycles, it ensures lasting performance. Our detector features a global database for accurate diagnostics across all ages and demographics.

71 Review(s)
Measurement Parameters baPWV (brachial-ankle pulse wave velocity)
ABI (brachial-ankle index)
BAI (body adiposity index)
HR (heart rate)
PVR (pulse wave recording)
SBP(systolic blood pressure)
DBP (diastolic blood pressure)
MAP(mean arterial pressure)
PP(pulse pressure)
Measurement Method Blood pressure measurement using oscillography
Pressurization Method Synchronized pressurization of limbs
Measurement Location Limbs (ankles, brachial arms)
Arm Circumference Range 20 to 38 cm
Lower Limb Width Range 16 to 33 cm
Blood Pressure Measurement Range 0 to 260 mmHg
Pulse Rate Measurement Range 40 to 199 BPM
Blood Pressure Module Accuracy ±3 mmHg under normal working environment
Measurement Accuracy < 0.4 kPa (±3 mmHg)
Repeatability < 0.533 kPa (4 mmHg)
Number of Blood Pressure Modules 4 (independent working blood pressure pumps)
Number of Cuff Cycles 8,000 inflation and deflation cycles
Database Global racial database capable of measuring populations up to age 100
Control System Branded industrial control computer
Data Connectivity Online transmission, remote management, and batch data upload
Display 12.1-inch HD LCD screen
Power Supply 115VA, voltage 220V
Battery Capacity 5200 mAh lithium battery
Battery Working Time Up to 3 hours
Dimensions 450 × 410 × 120 mm
Weight 7.8 kg
  • • Non-invasive detection
  • • Synchronized limb testing
  • • Multiple vascular readings
  • • Simultaneous four-limb testing
  • • Wide blood pressure range
  • • Pulse rate monitoring
  • • High accuracy and repeatability
  • • Global population compatibility
  • • Durable cuff performance
  • • Portable and lightweight
  • • Suitable for vascular diagnostics

  • Arteriosclerosis Detector MAD-701 is used in clinics and health centers for non-invasive assessment of arterial stiffness, lower extremity artery obstruction, and cardiovascular risk screening.

    • Industrial control computer system × 1 set

    • High-definition color LED display × 1 set

    • Logictech wireless mouse × 1 piece

    • Logictech Wireless keyboard × 1 piece

    • Cuff extension cable 2m × 1 set

    • Limbs Cuff × 1 set

    • PSB(3C) power cable × 1 root

  • Non-invasive detection

  • Synchronized limb testing

  • Multiple vascular readings

  • Simultaneous four-limb testing

  • Wide blood pressure range

  • Pulse rate monitoring

  • High accuracy and repeatability

  • Global population compatibility

  • Durable cuff performance

  • Portable and lightweight

  • Suitable for vascular diagnostics

  • Industrial control computer system × 1 set

  • High-definition color LED display × 1 set

  • Logictech wireless mouse × 1 piece

  • Logictech Wireless keyboard × 1 piece

  • Cuff extension cable 2m × 1 set

  • Limbs Cuff × 1 set

  • PSB(3C) power cable × 1 root

Arteriosclerosis Detector MAD-701 is used in clinics and health centers for non-invasive assessment of arterial stiffness, lower extremity artery obstruction, and cardiovascular risk screening.

Consult Our Experts

Frequently Asked questions

Q1

How does the device perform measurements?

The detector uses Oscillometric or Doppler-based methods for non-invasive arterial health assessments, ensuring accuracy and patient comfort.

Q2

How reliable is these Arteriosclerosis Detector?

These ensures precision and reliability with advanced measurement techniques, making it a trusted choice for vascular health assessments.

Q3

How does the device perform measurements?

These Arteriosclerosis Detector uses oscillometric or Doppler-based methods to ensure precise vascular assessments while maintaining patient comfort.

Q4

What display and interface features does the detector offer?

The device features high-resolution screens and intuitive interfaces, making navigation and data interpretation simple for healthcare professionals.

Q5

Is calibration or maintenance required for accurate readings?

Regular calibration and routine maintenance are recommended to ensure long-term accuracy and reliability.

Q6

Does the device allow for multi-limb assessments?

Yes, these enable simultaneous four-limb measurements, improving speed and accuracy in arteriosclerosis detection.