Arteriosclerosis Detector MAD-701 supports a wide blood pressure measurement range from 0 to 260 mmHg and a pulse rate range of 40 to 199 BPM. It uses oscillography blood pressure measurement and synchronized limb pressurization for simultaneous four-limb testing. With four pressure modules and durable cuffs supporting 8,000 cycles, it ensures lasting performance. Our detector features a global database for accurate diagnostics across all ages and demographics.
| Measurement Parameters | baPWV (brachial-ankle pulse wave velocity) ABI (brachial-ankle index) BAI (body adiposity index) HR (heart rate) PVR (pulse wave recording) SBP(systolic blood pressure) DBP (diastolic blood pressure) MAP(mean arterial pressure) PP(pulse pressure) |
|---|---|
| Measurement Method | Blood pressure measurement using oscillography |
| Pressurization Method | Synchronized pressurization of limbs |
| Measurement Location | Limbs (ankles, brachial arms) |
| Arm Circumference Range | 20 to 38 cm |
| Lower Limb Width Range | 16 to 33 cm |
| Blood Pressure Measurement Range | 0 to 260 mmHg |
| Pulse Rate Measurement Range | 40 to 199 BPM |
| Blood Pressure Module Accuracy | ±3 mmHg under normal working environment |
| Measurement Accuracy | < 0.4 kPa (±3 mmHg) |
| Repeatability | < 0.533 kPa (4 mmHg) |
| Number of Blood Pressure Modules | 4 (independent working blood pressure pumps) |
| Number of Cuff Cycles | 8,000 inflation and deflation cycles |
| Database | Global racial database capable of measuring populations up to age 100 |
| Control System | Branded industrial control computer |
| Data Connectivity | Online transmission, remote management, and batch data upload |
| Display | 12.1-inch HD LCD screen |
| Power Supply | 115VA, voltage 220V |
| Battery Capacity | 5200 mAh lithium battery |
| Battery Working Time | Up to 3 hours |
| Dimensions | 450 × 410 × 120 mm |
| Weight | 7.8 kg |
Non-invasive detection
Synchronized limb testing
Multiple vascular readings
Simultaneous four-limb testing
Wide blood pressure range
Pulse rate monitoring
High accuracy and repeatability
Global population compatibility
Durable cuff performance
Portable and lightweight
Suitable for vascular diagnostics
Arteriosclerosis Detector MAD-701 is used in clinics and health centers for non-invasive assessment of arterial stiffness, lower extremity artery obstruction, and cardiovascular risk screening.
Industrial control computer system × 1 set
High-definition color LED display × 1 set
Logictech wireless mouse × 1 piece
Logictech Wireless keyboard × 1 piece
Cuff extension cable 2m × 1 set
Limbs Cuff × 1 set
PSB(3C) power cable × 1 root