Electrosurgical Unit MEU-704 offers various cutting configurations, including Pure Cut with a maximum output power of 100 W in its monopolar mode. For more advanced tissue dissection, its Blend 1 and Blend 2 modes delivers up to 100 W of power at 500-ohm impedance. In coagulation mode, this unit features Spray and Forced Coagulation settings. Overall, it is engineered to provide safe, versatile, and efficient energy solutions across a wide range of surgical applications.
| Monopolar - Cut - Pure Cut Max Output Power | 100W |
| Monopolar - Cut - Pure Cut Load Impedance | 500Ω |
| Monopolar - Cut - Pure Cut Max Output Voltage | 1300V |
| Monopolar - Cut - Pure Cut Crest Factor | 1.8 |
| Monopolar - Cut - Blend 1 Max Output Power | 100W |
| Monopolar - Cut - Blend 1 Load Impedance | 500Ω |
| Monopolar - Cut - Blend 1 Modulation Frequency | 20kHz |
| Monopolar - Cut - Blend 1 Max Output Voltage | 1400V |
| Monopolar - Cut - Blend 1 Crest Factor | 2.0 |
| Monopolar - Cut - Blend 2 Max Output Power | 100W |
| Monopolar - Cut - Blend 2 Load Impedance | 500Ω |
| Monopolar - Cut - Blend 2 Modulation Frequency | 20kHz |
| Monopolar - Cut - Blend 2 Max Output Voltage | 1300V |
| Monopolar - Cut - Blend 2 Crest Factor | 2.0 |
| Monopolar - Coag – Spray Max Output Power | 90W |
| Monopolar - Coag – Spray Load Impedance | 500Ω |
| Monopolar - Coag – Spray Modulation Frequency | 12 to 24kHz |
| Monopolar - Coag – Spray Max Output Voltage | 4800V |
| Monopolar - Coag – Spray Crest Factor | 6.3 |
| Monopolar - Coag – Forced Max Output Power | 60W |
| Monopolar - Coag – Forced Load Impedance | 500Ω |
| Monopolar - Coag – Forced Modulation Frequency | 25kHz |
| Monopolar - Coag – Forced Max Output Voltage | 4800V |
| Monopolar - Coag – Forced Crest Factor | 6.2 |
| Bipolar – Standard Max Output Power | 60W |
| Bipolar – Standard Load Impedance | 100Ω |
| Bipolar – Standard Modulation Frequency | 20kHz |
| Bipolar – Standard Max Output Voltage | 700V |
| Bipolar – Standard Crest Factor | 1.9 |
Our Electrosurgical Unit MEU-704 is capable of handling most monopolar and bipolar applications, ideal for soft tissue surgeries, dissection, and hemostasis across a variety of animal species.
| Accessories Name | Quantity |
| Monopolar Foot-Switch | 1 pc |
| Hand-Switch Pencil, Disposable | 1 pc |
| Patient Return Electrode with Cable, Reusable | 1 pc |
| Patient Return Electrode Rods (10mm) with Cable, Reusable | 1 pc |
| Bipolar Forceps, Reusable, Connecting Cable | 1 pc |
Accessories Name Quantity Monopolar Foot-Switch 1 pc Hand-Switch Pencil, Disposable 1 pc Patient Return Electrode with Cable, Reusable 1 pc Patient Return Electrode Rods (10mm) with Cable, Reusable 1 pc Bipolar Forceps, Reusable, Connecting Cable 1 pc
Our Electrosurgical Unit MEU-704 is capable of handling most monopolar and bipolar applications, ideal for soft tissue surgeries, dissection, and hemostasis across a variety of animal species.
Consult Our Experts
Frequently Asked questions
What types of surgical modes are available in the Electrosurgical Unit?
It offers versatile surgical modes, including multiple monopolar cutting options like Pure Cut, Blend 1, and Blend 2, each delivering up to 100W of power. For coagulation, it features Spray and Forced Coagulation modes, and it also includes a bipolar output mode for delicate surgical tasks.
Is the Electrosurgical Unit suitable for veterinary procedures?
Yes, it is specifically designed for veterinary use, offering reliable performance for soft tissue surgeries, dissection, and hemostasis across a wide range of animal species. It supports both monopolar and bipolar techniques commonly used in veterinary practices.
What safety features are included in the Electrosurgical Unit?
It includes a CQM (Contact Quality Monitoring) System that ensures optimal electrode contact during procedures, minimizing risks. Its modern user interface and quick adjustment functions enhance usability and operational safety.
What is the maximum output power for cutting and coagulation in the?
In monopolar cutting modes (Pure, Blend 1, Blend 2), it delivers up to 100W of power. For monopolar coagulation (Spray and Forced), it offers 90W and 60W, respectively. The bipolar mode provides a maximum of 60W, making it efficient across a range of surgical scenarios.
What kind of electrode monitoring system does this Electrosurgical Unit include?
It features a Contact Quality Monitoring (CQM) System for safety.
Does the Electrosurgical Unit include a footswitch?
Yes, a Monopolar Foot-Switch is included as a standard accessory.
Is the Electrosurgical Unit easy to operate during surgeries?
Yes, it features a modern UI, comprehensive controls, and quick adjustment functions for efficient operation.
Is the Electrosurgical Unit suitable for gynecology procedures?
Absolutely, it's designed for safe and precise use in gynecological surgeries.
What safety features are included in the Electrosurgical Unit?
It includes the CQM (Contact Quality Monitoring) system, foot switch and pen controls, and quick adjustment settings.
How does the Electrosurgical Unit ensure patient safety during procedures?
The Electrosurgical Unit is equipped with the CQM Contact Quality Monitoring System, which continuously monitors electrode contact quality. This minimizes the risk of accidental burns or ineffective energy delivery, ensuring maximum patient safety during surgical procedures.
What makes the Electrosurgical Unit ideal for multi-disciplinary surgical departments?
With a power output range from 50W to 400W and advanced modulation frequencies, the Electrosurgical Unit offers versatile performance across departments. It's suitable for general surgery, gynecology, urology, ENT, pediatric, and veterinary procedures—making it a universal tool in modern operating rooms.
Can the Electrosurgical Unit be used in minimally invasive surgeries?
Yes, the precision cutting and coagulation capabilities of the Electrosurgical Unit, combined with intuitive controls and safety features, make it well-suited for both open and minimally invasive procedures.
How does the Electrosurgical Unit improve efficiency in the operating room?
Its quick power and volume adjustment capabilities, combined with high cutting and coagulation performance, enable faster setup and operation times. This improves surgical precision and reduces procedural delays, leading to better outcomes and productivity.