Blood Gas Analyzer MBGA-703 calculates over 32 parameters and utilizes disposable dry lactate-glucose electrodes with a lifespan of up to 30 days. It features a 12.1-inch colour LCD touchscreen and ample data storage. It measures pO₂, pCO₂, electrolytes, glucose, and lactate with automated handling. Ideal for hospitals, ICUs, and laboratories, Blood Gas Analyzer MBGA-703 delivers fast and accurate blood gas analysis.
| Measured Parameters | pO₂, pCO₂, Hct, K⁺, Na⁺, Cl⁻, Ca²⁺, Glu, Lac |
| Sample Type | Whole Blood, Arterial Blood, Venous Blood, Serum, Plasma, CSF |
| Total Calculated Parameters | More than 32 |
| Electrode Technology | Disposable dry lactate-glucose electrode, up to 30 days usage |
| Display | 12.1 inches colour LCD touch screen, large data storage space |
| Ease of Use | Video instructions and online help |
Blood Gas Analyzer MBGA-703 features innovative electrodes with 30-day disposable lactate-glucose electrodes for reliable, low-maintenance use. Video instructions and online support ensure easy operation for healthcare professionals.
PCO2/PCO2 intergrated Electrode (6 months warranty) | 1 |
TH/HCT intergrated electrode | 1 |
Ref electrode | 1 |
pH electrode | 1 |
K electrode | 1 |
Na electrode | 1 |
Cl electrode | 1 |
Ca electrode | 1 |
Lac/GLU intergrated Electrode | 1 |
Ion Electrode Sealing Ring |
|
pCO2, pO2 electrode sealing ring (Silicon rubber φ2.8 x 2.0 mm) |
|
| Needle for blockage elimination (φ0.6 x 160mm) |
|
Auxiliary pump tube for Blood Gas BPT, (1.6 x 4.8 x 3) |
|
Tektronix Tube (φ2.5x 0.8mm x 120mm)-only for probe |
|
Tektronix Tube (φ2.74 x 1.02mm x 200mm)-only for pump |
|
Printer paper (φ50 x 80mm) |
|
Needle wiper |
|
Resistive touch pen (0.5 x 150mm) |
|
Maintenance electrode A |
|
Maintenance electrode B |
|
Ion Dummy electrode (optional) |
|
O’ ring (2.6mmx 1.9mm) |
|
Power cord |
|
Fuse |
|
Quality control | H:2mlx10+ M:2mlx10+ L:2mx10, per pack |
Quality control | H:2ml x 30 or M:2ml x 30, or L:2ml x 30 per pack |
Blood Gas Reagent Pack | 50 tests per pack with 45 days validity |
Blood Gas Reagent Pack | 75 tests per pack with 45 days validity |
Blood Gas Reagent Pack | 100 tests per pack with 45 days validity |
Blood Gas Reagent Pack | 150 tests per pack with 46 days validity |
Blood Gas Reagent Pack | 200 tests per pack with 45 days validity |
Blood Gas Reagent Pack | 300 tests per pack with 45 days validity |
Blood Gas Reagent Pack | 400 tests per pack with 45 days validity |
Blood Gas Reagent Pack | 500 tests per pack with 45 days validity |
Blood Gas Reagent Pack | 50 tests per pack with 45 days validity |
Blood Gas Reagent Pack | 75 tests per pack with 45 days validity |
Blood Gas Reagent Pack | 100 tests per pack with 45 days validity |
Blood Gas Reagent Pack | 150 tests per pack with 46 days validity |
Blood Gas Reagent Pack | 200 tests per pack with 45 days validity |
Blood Gas Reagent Pack | 300 tests per pack with 45 days validity |
Blood Gas Reagent Pack | 400 tests per pack with 45 days validity |
Blood Gas Reagent Pack | 500 tests per pack with 45 days validity |
Flush solutions (without GLU/LAC) |
|
Flush solutions (with GLU/LAC) |
|
Refill solution for ISE electrodes | K/Na/Cl/Ca/pH, 0.8mlx 5pieces |
Refill solution for Ref electrode | 20ml x1piece |
Refill solution for pO2 electrode | 1PCS |
Refill solution for pCO2 electrode | 1PCS |
multi-Enzyme Deproteinizer |
|
Automated sample handling
Innovative electrode technology
Integrated flush solution pack
Uninterrupted power supply
User-friendly operation
PCO2/PCO2 intergrated Electrode (6 months warranty) 1 TH/HCT intergrated electrode 1 Ref electrode 1 pH electrode 1 K electrode 1 Na electrode 1 Cl electrode 1 Ca electrode 1 Lac/GLU intergrated Electrode 1 Ion Electrode Sealing Ring pCO2, pO2 electrode sealing ring (Silicon rubber φ2.8 x 2.0 mm) Auxiliary pump tube for Blood Gas BPT, (1.6 x 4.8 x 3) Tektronix Tube (φ2.5x 0.8mm x 120mm)-only for probe Tektronix Tube (φ2.74 x 1.02mm x 200mm)-only for pump Printer paper (φ50 x 80mm) Needle wiper Resistive touch pen (0.5 x 150mm) Maintenance electrode A Maintenance electrode B Ion Dummy electrode (optional) O’ ring (2.6mmx 1.9mm) Power cord Fuse Quality control H:2mlx10+ M:2mlx10+ L:2mx10, per pack Quality control H:2ml x 30 or M:2ml x 30, or L:2ml x 30 per pack Blood Gas Reagent Pack 50 tests per pack with 45 days validity Blood Gas Reagent Pack 75 tests per pack with 45 days validity Blood Gas Reagent Pack 100 tests per pack with 45 days validity Blood Gas Reagent Pack 150 tests per pack with 46 days validity Blood Gas Reagent Pack 200 tests per pack with 45 days validity Blood Gas Reagent Pack 300 tests per pack with 45 days validity Blood Gas Reagent Pack 400 tests per pack with 45 days validity Blood Gas Reagent Pack 500 tests per pack with 45 days validity Blood Gas Reagent Pack 50 tests per pack with 45 days validity Blood Gas Reagent Pack 75 tests per pack with 45 days validity Blood Gas Reagent Pack 100 tests per pack with 45 days validity Blood Gas Reagent Pack 150 tests per pack with 46 days validity Blood Gas Reagent Pack 200 tests per pack with 45 days validity Blood Gas Reagent Pack 300 tests per pack with 45 days validity Blood Gas Reagent Pack 400 tests per pack with 45 days validity Blood Gas Reagent Pack 500 tests per pack with 45 days validity Flush solutions (without GLU/LAC) Flush solutions (with GLU/LAC) Refill solution for ISE electrodes K/Na/Cl/Ca/pH, 0.8mlx 5pieces Refill solution for Ref electrode 20ml x1piece Refill solution for pO2 electrode 1PCS Refill solution for pCO2 electrode 1PCS multi-Enzyme Deproteinizer Needle for blockage elimination (φ0.6 x 160mm)
Blood Gas Analyzer MBGA-703 features innovative electrodes with 30-day disposable lactate-glucose electrodes for reliable, low-maintenance use. Video instructions and online support ensure easy operation for healthcare professionals.
Consult Our Experts
Frequently Asked questions
What is the minimum sample volume required?
Blood Gas Analyzer MBGA-703 requires a small sample volume, making it suitable for neonatal and pediatric applications.
What happens if an air bubble is detected in the sample?
The analyzer includes an air detection system that prompts the user to correct the sample before analysis.
What is the lifespan of the flush solution pack?
The integrated flush solution pack is designed for extended use and should be replaced as per the device's maintenance schedule.
What if the device is not reading a sample correctly?
Ensure the sample is properly prepared, check for air bubbles, and confirm the correct insertion of the sample container.
How is the blood sample prepared for analysis?
The blood sample should be collected in a heparinized syringe or tube to prevent clotting. It is then carefully handled and placed in the analyzer for automated processing.
Is real-time monitoring possible with this device?
While the analyzer provides rapid results, real-time patient monitoring typically requires additional devices such as continuous blood gas monitors.
How does the analyzer contribute to patient safety?
By providing timely and accurate results, Blood Gas Analyzer enables immediate clinical decision-making, reducing the risk of complications from delayed treatment.
What technology does this Analyzer use?
It utilizes advanced electrochemical and optical sensor technologies to ensure precise measurement of blood gases, electrolytes, and metabolites, minimizing error rates.
Do these Analyzers require special reagents?
Yes, specific reagents are required to measure different parameters accurately. These reagents must be stored properly and used as per the manufacturer’s guidelines.
Can results from the Analyzer be printed or saved digitally?
Yes, these Blood Gas Analyzer supports digital data storage and printing, allowing healthcare providers to document and track patient results efficiently.