Electrosurgical Unit MEU-706 delivers up to 100 W of power in Pure Cut mode, ensuring clean and efficient tissue dissection. Its enhanced cutting options such as Blend 1 and Blend 2 also provide 100 W power with modulation frequencies, allowing for tailored tissue effects. Its Forced Coag mode offers deeper and more controlled coagulation. Additionally, this ESU is engineered for versatility, safety, and optimized performance across a wide range of surgical applications.
| Monopolar - Cut - Pure Cut Max Output Power | 100W |
| Monopolar - Cut - Pure Cut Load Impedance | 500Ω |
| Monopolar - Cut - Pure Cut Max Output Voltage | 1300V |
| Monopolar - Cut - Pure Cut Crest Factor | 1.8 |
| Monopolar - Cut - Blend 1 Max Output Power | 100W |
| Monopolar - Cut - Blend 1 Load Impedance | 500Ω |
| Monopolar - Cut - Blend 1 Modulation Frequency | 20kHz |
| Monopolar - Cut - Blend 1 Max Output Voltage | 1400V |
| Monopolar - Cut - Blend 1 Crest Factor | 2.0 |
| Monopolar - Cut - Blend 2 Max Output Power | 100W |
| Monopolar - Cut - Blend 2 Load Impedance | 500Ω |
| Monopolar - Cut - Blend 2 Modulation Frequency | 20kHz |
| Monopolar - Cut - Blend 2 Max Output Voltage | 1300V |
| Monopolar - Cut - Blend 2 Crest Factor | 2.0 |
| Monopolar - Coag – Spray Max Output Power | 90W |
| Monopolar - Coag – Spray Load Impedance | 500Ω |
| Monopolar - Coag – Spray Modulation Frequency | 12 to 24kHz |
| Monopolar - Coag – Spray Max Output Voltage | 4800V |
| Monopolar - Coag – Spray Crest Factor | 6.3 |
| Monopolar - Coag – Forced Max Output Power | 60W |
| Monopolar - Coag – Forced Load Impedance | 500Ω |
| Monopolar - Coag – Forced Modulation Frequency | 25kHz |
| Monopolar - Coag – Forced Max Output Voltage | 4800V |
| Monopolar - Coag – Forced Crest Factor | 6.2 |
| Bipolar – Standard Max Output Power | 60W |
| Bipolar – Standard Load Impedance | 100Ω |
| Bipolar – Standard Modulation Frequency | 20kHz |
| Bipolar – Standard Max Output Voltage | 700V |
| Bipolar – Standard Crest Factor | 1.9 |
Our Electrosurgical Unit MEU-706 satisfies the veterinarian’s demands with precision, safety, and reliability. It is designed to meet the diverse needs of veterinary surgical procedures, ensuring effective tissue cutting and coagulation with minimal thermal damage.
| Accessories Name | Quantity |
| Monopolar Foot-Switch | 1 pc |
| Bipolar Foot-Switch | 1 pc |
| Hand-Switch Pencil, Disposable | 1 pc |
| Patient Return Electrode Rods (10mm) With Cable, Reusable | 1 pc |
| Bipolar Forceps, Reusable, Connecting Cable | 1 pc |
Accessories Name Quantity Monopolar Foot-Switch 1 pc Bipolar Foot-Switch 1 pc Hand-Switch Pencil, Disposable 1 pc Patient Return Electrode Rods (10mm) With Cable, Reusable 1 pc Bipolar Forceps, Reusable, Connecting Cable 1 pc
Our Electrosurgical Unit MEU-706 satisfies the veterinarian’s demands with precision, safety, and reliability. It is designed to meet the diverse needs of veterinary surgical procedures, ensuring effective tissue cutting and coagulation with minimal thermal damage.
Consult Our Experts
Frequently Asked questions
Can the Electrosurgical Unit be used for veterinary surgeries?
Yes, it is specifically designed for veterinary surgical applications, including soft tissue, orthopedic, and animal surgeries.
Is there a vessel sealing feature in the Electrosurgical Unit?
Yes, it includes vessel sealing technology, ensuring reliable tissue fusion in veterinary procedures.
What are the key features of the Electrosurgical Unit, and how do they support veterinary surgeries?
The Electrosurgical Unit is designed with advanced features, including a high-resolution color touchscreen, multiple working modes (such as Blend 1 and 2, Pure Cut, and Coagulation), and vessel sealing technology. These features ensure that the unit can be used for a wide range of veterinary surgeries, from delicate tissue cutting to efficient coagulation and vessel sealing, ensuring precision and reliability during procedures.
What types of surgical applications is the Electrosurgical Unit most suitable for?
The Electrosurgical Unit is ideal for a wide range of veterinary surgical applications, including soft tissue surgeries, orthopedic procedures, and both large and small animal surgeries. It is designed to offer high precision in cutting, coagulation, and vessel sealing, making it versatile for various types of surgeries in veterinary practice.
How does the Electrosurgical Unit ensure safety and reliability during surgeries?
The Electrosurgical Unit ensures safety and reliability through its stable performance in both monopolar and bipolar modes, as well as its advanced safety features, such as power adjustment, parameter display, and intermittent operation. The unit is designed to adapt to a wide range of surgical needs, offering controlled energy output and reducing the risk of thermal injury to surrounding tissues.
Is the Electrosurgical Unit suitable for gynecology procedures?
Absolutely, it's designed for safe and precise use in gynecological surgeries.
What safety features are included in the Electrosurgical Unit?
It includes the CQM (Contact Quality Monitoring) system, foot switch and pen controls, and quick adjustment settings.
How does the Electrosurgical Unit ensure patient safety during procedures?
The Electrosurgical Unit is equipped with the CQM Contact Quality Monitoring System, which continuously monitors electrode contact quality. This minimizes the risk of accidental burns or ineffective energy delivery, ensuring maximum patient safety during surgical procedures.
What makes the Electrosurgical Unit ideal for multi-disciplinary surgical departments?
With a power output range from 50W to 400W and advanced modulation frequencies, the Electrosurgical Unit offers versatile performance across departments. It's suitable for general surgery, gynecology, urology, ENT, pediatric, and veterinary procedures—making it a universal tool in modern operating rooms.
Can the Electrosurgical Unit be used in minimally invasive surgeries?
Yes, the precision cutting and coagulation capabilities of the Electrosurgical Unit, combined with intuitive controls and safety features, make it well-suited for both open and minimally invasive procedures.
How does the Electrosurgical Unit improve efficiency in the operating room?
Its quick power and volume adjustment capabilities, combined with high cutting and coagulation performance, enable faster setup and operation times. This improves surgical precision and reduces procedural delays, leading to better outcomes and productivity.