Electrosurgical Unit MEU-701 offers Pure Cut with blends ranging from 150 W to 250 W, and modulation frequencies for smooth, controlled incisions. It features both Monopolar and Bipolar modes, offering tailored energy delivery for different surgical needs. Its Bipolar mode supports Macro, Standard, and Fine settings, offering power outputs from 50 W to 150 W, optimized for delicate and confined surgical sites. With adjustable load impedance ranges and precise voltage control, this unit ensures reliable performance, patient safety, and optimal surgical outcomes.
| Monopolar - Cut - Pure Cut Max Output Power | 300W |
| Monopolar - Cut - Pure Cut Load Impedance | 500Ω |
| Monopolar - Cut - Pure Cut Modulation Frequency | - |
| Monopolar - Cut - Pure Cut Max Output Voltage | 1300V |
| Monopolar - Cut - Pure Cut Crest Factor | 1.8 |
| Monopolar - Cut - Blend 1 Max Output Power | 250W |
| Monopolar - Cut - Blend 1 Load Impedance | 500Ω |
| Monopolar - Cut - Blend 1 Modulation Frequency | 20kHz |
| Monopolar - Cut - Blend 1 Max Output Voltage | 1400V |
| Monopolar - Cut - Blend 1 Crest Factor | 2.0 |
| Monopolar - Cut - Blend 2 Max Output Power | 200W |
| Monopolar - Cut - Blend 2 Load Impedance | 500Ω |
| Monopolar - Cut - Blend 2 Max Output Voltage | 1300V |
| Monopolar - Cut - Blend 2 Crest Factor | 2.0 |
| Monopolar - Cut - Blend 3 Max Output Power | 150W |
| Monopolar - Cut - Blend 3 Load Impedance | 500Ω |
| Monopolar - Cut - Blend 3 Modulation Frequency | 20kHz |
| Monopolar - Cut - Blend 3 Max Output Voltage | 1400V |
| Monopolar - Cut - Blend 3 Crest Factor | 1.9 |
| Monopolar - Coag - Spray Max Output Power | 120W |
| Monopolar - Coag - Spray Load Impedance | 500Ω |
| Monopolar - Coag - Spray Modulation Frequency | 12 to 24kHz |
| Monopolar - Coag - Spray Max Output Voltage | 4800V |
| Monopolar - Coag - Spray Crest Factor | 6.3 |
| Monopolar - Coag - Forced Max Output Power | 120W |
| Monopolar - Coag - Forced Load Impedance | 500Ω |
| Monopolar - Coag - Forced Modulation Frequency | 25kHz |
| Monopolar - Coag - Forced Max Output Voltage | 4800V |
| Monopolar - Coag - Forced Crest Factor | 6.2 |
| Monopolar - Coag - Soft Max Output Power | 120W |
| Monopolar - Coag - Soft Load Impedance | 500Ω |
| Monopolar - Coag - Soft Modulation Frequency | 20kHz |
| Monopolar - Coag - Soft Max Output Voltage | 1000V |
| Monopolar - Coag - Soft Crest Factor | 2.0 |
| Bipolar - Macro Max Output Power | 150W |
| Bipolar - Macro Load Impedance | 100Ω |
| Bipolar - Macro Modulation Frequency | - |
| Bipolar - Macro Max Output Voltage | 500V |
| Bipolar - Macro Crest Factor | 1.6 |
| Bipolar - Standard Max Output Power | 100W |
| Bipolar - Standard Load Impedance | 100Ω |
| Bipolar - Standard Modulation Frequency | 20kHz |
| Bipolar - Standard Max Output Voltage | 700V |
| Bipolar - Standard Crest Factor | 1.9 |
| Bipolar - Fine Max Output Power | 50W |
| Bipolar - Fine Load Impedance | 100Ω |
| Bipolar - Fine Modulation Frequency | 20kHz |
| Bipolar - Fine Max Output Voltage | 400V |
| Bipolar - Fine Crest Factor | 1.9 |
Our Electrosurgical Unit MEU-701 is designed to meet the diverse needs of modern surgical practices, ensuring safe and efficient performance in various departments, including endoscopy, gastroenterology, gynecology, urology, pediatrics, and other surgical disciplines.
| Accessories Name | Quantity |
| Monopolar Foot-Switch | 1 pc |
| Bipolar Foot-Switch | 1 pc |
| Hand-Switch Pencil, Disposable | 1 pc |
| Patient Return Electrode Without Cable, Split, for Adult, Disposable | 1 pc |
| Connecting Cable for Patient Return Electrode (Split), 3m, Reusable | 1 pc |
| Blade Electrode (16.51 cm) | 1 pc |
| Monopolar Adapter | 1 pc |
| Laparoscopic Bipolar High Frequency Cable | 1 pc |
| Laparoscopic Monopolar High Frequency Cable | 1 pc |
| Bipolar Forceps, Reusable, with Connecting Cable | 1 pc |
| Monopolar Foot-Switch | 1 pc |
Accessories Name Quantity Monopolar Foot-Switch 1 pc Bipolar Foot-Switch 1 pc Hand-Switch Pencil, Disposable 1 pc Patient Return Electrode Without Cable, Split, for Adult, Disposable 1 pc Connecting Cable for Patient Return Electrode (Split), 3m, Reusable 1 pc Blade Electrode (16.51 cm) 1 pc Monopolar Adapter 1 pc Laparoscopic Bipolar High Frequency Cable 1 pc Laparoscopic Monopolar High Frequency Cable 1 pc Bipolar Forceps, Reusable, with Connecting Cable 1 pc Monopolar Foot-Switch 1 pc
Our Electrosurgical Unit MEU-701 is designed to meet the diverse needs of modern surgical practices, ensuring safe and efficient performance in various departments, including endoscopy, gastroenterology, gynecology, urology, pediatrics, and other surgical disciplines.
Consult Our Experts
Frequently Asked questions
What is the Electrosurgical Unit used for?
It's used for precise surgical cutting and coagulation in procedures across gynecology, urology, gastroenterology, and more.
What cutting and coagulation modes does the Electrosurgical Unit offer?
It provides multiple Monopolar Cut options including Pure Cut (up to 300W) and three Blend modes with varying modulation frequencies (up to 250W). For coagulation, it offers Spray, Forced, and Soft modes. On the Bipolar side, it has Macro, Standard, and Fine settings with power outputs tailored to delicate surgical work.
How does the Electrosurgical Unit enhance safety during operations?
This unit features advanced safety mechanisms, precise voltage control, compatibility with various load impedances, and includes a patient return electrode with split design to monitor and protect against thermal injuries. Its user-friendly interface also allows for real-time adjustments to ensure accurate and safe performance.
Can the Electrosurgical Unit be integrated into laparoscopic procedures?
Absolutely. It includes dedicated high-frequency cables for both laparoscopic monopolar and bipolar surgeries. This ensures it can be smoothly integrated into minimally invasive surgical workflows while delivering precise energy control.
Can the Electrosurgical Unit be used for delicate procedures?
Yes, its Bipolar Fine mode (50W max) is ideal for delicate and confined surgical sites.
Is the Electrosurgical Unit easy to use in a surgical setting?
Yes. It has a user-friendly interface that allows quick adjustment of power levels and settings. It also supports both hand-switch and foot-switch operation, enhancing flexibility during procedures.
Is the Electrosurgical Unit suitable for gynecology procedures?
Absolutely, it's designed for safe and precise use in gynecological surgeries.
What safety features are included in the Electrosurgical Unit?
It includes the CQM (Contact Quality Monitoring) system, foot switch and pen controls, and quick adjustment settings.
How does the Electrosurgical Unit ensure patient safety during procedures?
The Electrosurgical Unit is equipped with the CQM Contact Quality Monitoring System, which continuously monitors electrode contact quality. This minimizes the risk of accidental burns or ineffective energy delivery, ensuring maximum patient safety during surgical procedures.
What makes the Electrosurgical Unit ideal for multi-disciplinary surgical departments?
With a power output range from 50W to 400W and advanced modulation frequencies, the Electrosurgical Unit offers versatile performance across departments. It's suitable for general surgery, gynecology, urology, ENT, pediatric, and veterinary procedures—making it a universal tool in modern operating rooms.
Can the Electrosurgical Unit be used in minimally invasive surgeries?
Yes, the precision cutting and coagulation capabilities of the Electrosurgical Unit, combined with intuitive controls and safety features, make it well-suited for both open and minimally invasive procedures.
How does the Electrosurgical Unit improve efficiency in the operating room?
Its quick power and volume adjustment capabilities, combined with high cutting and coagulation performance, enable faster setup and operation times. This improves surgical precision and reduces procedural delays, leading to better outcomes and productivity.