Holter Monitor MHM-701 records 12-channel digital ECG data with 12-bit resolution. It provides accurate and high-quality results over a 24-hour monitoring period. This device has a frequency response of 0.1 to 60 Hz and a sampling rate of 250 Hz. This ensures clear and detailed waveforms for clinical analysis. Its compact and lightweight design makes it easy to wear. With options like a belt clip and lanyard, patients can move freely and comfortably during monitoring.

51 Review(s)
Channels 12 Channel Digital Recording
Resolution 12 Bit
Frequency Response 0.1 to 60 Hz
Sampling Rate 250 Hz
Minimum Input Signal 50 µV
Sensitivity 10 mm/mV ±5%
Input Impedance >10 MΩ
Baseline Stability ≤ ±5%
Time Constant ≥ 3.2 s
CMRR >60 dB
Inter-channel Interference <0.15 mV
Memory Capacity ≥ 256 MB
Data Transfer Built-in SD Card
ECG Signal Verification LCD at Hook-up
Operating Temperature 0°C to +45°C
Non-operating Temperature 0°C to +60°C
Operating Humidity 10% to 95% (non-condensing)
Non-operating Humidity 5% to 95% (non-condensing)
Atmospheric Pressure 86 kPa to 106 kPa
Monitor 15inch with 1024×768 resolution or above
Patient Cable 12 Lead Integrated Patient Cable
Operating Position Belt Clip
Input Circuit Current <0.1 µA
Safety Level Class I
RAM 1 GB
Storage 40 GB free space on hard drive
USB Ports 2 Free
Printer Laser Printer
CPU Intel Pentium 4
Dynamic Input Voltage ±4.5 mV
Polarizing Voltage ±300 mV
Battery 1 AA Alkaline (1.5V, 24 hours typical)
Power Consumption <0.1 VA
Packaging Dimensions 30 × 25 × 20 cm
Gross Weight 2 kg
  • • Advanced Recording Capabilities
  • • High Sensitivity and Signal Quality
  • • Robust Data Storage and Transfer
  • • Low Power Consumption
  • • Minimum System Requirements

  • Our Holter Monitor MHM-701 plays an important role in evaluating the effectiveness of anti-arrhythmic treatments and monitoring pacemaker performance. Designed for use in both hospital and ambulatory settings, it delivers continuous, real-time ECG data to support accurate diagnoses and guide clinical decision-making.

  • Advanced Recording Capabilities

  • High Sensitivity and Signal Quality

  • Robust Data Storage and Transfer

  • Low Power Consumption

  • Minimum System Requirements

Our Holter Monitor MHM-701 plays an important role in evaluating the effectiveness of anti-arrhythmic treatments and monitoring pacemaker performance. Designed for use in both hospital and ambulatory settings, it delivers continuous, real-time ECG data to support accurate diagnoses and guide clinical decision-making.

Consult Our Experts

Frequently Asked questions

Q1

Is the Holter Monitor comfortable to wear?

Yes, it is designed for comfort. The compact recording unit is lightweight and can be worn discreetly without interrupting daily activities.

Q2

Will the Holter Monitor affect my daily activities?

No, the device is designed for seamless use, allowing you to go about your routine with minimal disruption.

Q3

How is the recorded data analyzed?

After the monitoring period ends, the device's data is transferred to a computer for analysis. Cardiologists examine the ECG patterns to detect irregularities and diagnose heart conditions.

Q4

Does the Holter Monitor require battery changes?

No, the device comes with a built-in power source that lasts through the recording period.

Q5

How long does the Holter Monitor record data?

The device can record heart activity for 24 to 48 hours or even longer, depending on the doctor’s recommendation.