Electrosurgical Unit MEU-705 supports Blend 1 and Blend 2 modes, each delivering up to 100W at 500Ω, with modulation frequencies levels. For coagulation, its monopolar Spray mode offers high-voltage output of 90W with a wide frequency range and a high crest factor. In bipolar mode, this unit features vessel sealing technology with stable performance parameters, ensuring reliable tissue fusion. In addition, it ensures safety and adaptability across a range of surgical applications, from delicate vessel sealing to high-power cutting and coagulation.
| Monopolar - Cut - Pure Cut Max Output Power | 100W |
|---|---|
| Monopolar - Cut - Pure Cut Load Impedance | 500Ω |
| Monopolar - Cut - Pure Cut Max Output Voltage | 1300V |
| Monopolar - Cut - Pure Cut Crest Factor | 1.8 |
| Monopolar - Cut - Blend 1 Max Output Power | 100W |
| Monopolar - Cut - Blend 1 Load Impedance | 500Ω |
| Monopolar - Cut - Blend 1 Modulation Frequency | 20kHz |
| Monopolar - Cut - Blend 1 Max Output Voltage | 1400V |
| Monopolar - Cut - Blend 1 Crest Factor | 2.0 |
| Monopolar - Cut - Blend 2 Max Output Power | 100W |
| Monopolar - Cut - Blend 2 Load Impedance | 500Ω |
| Monopolar - Cut - Blend 2 Modulation Frequency | 20kHz |
| Monopolar - Cut - Blend 2 Max Output Voltage | 1300V |
| Monopolar - Cut - Blend 2 Crest Factor | 2.0 |
| Monopolar - Coag – Spray Max Output Power | 90W |
| Monopolar - Coag – Spray Load Impedance | 500Ω |
| Monopolar - Coag – Spray Modulation Frequency | 12 to 24kHz |
| Monopolar - Coag – Spray Max Output Voltage | 4800V |
| Monopolar - Coag – Spray Crest Factor | 6.3 |
| Monopolar - Coag – Forced Max Output Power | 60W |
| Monopolar - Coag – Forced Load Impedance | 500Ω |
| Monopolar - Coag – Forced Modulation Frequency | 25kHz |
| Monopolar - Coag – Forced Max Output Voltage | 4800V |
| Monopolar - Coag – Forced Crest Factor | 6.2 |
| Bipolar – Vessel Sealing Load Impedance | 100Ω |
| Bipolar – Vessel Sealing Modulation Frequency | 20kHz |
| Bipolar – Vessel Sealing Max Output Voltage | 700V |
| Bipolar – Vessel Sealing Crest Factor | 1.9 |
| Bipolar – Standard Max Output Power | 60W |
| Bipolar – Standard Load Impedance | 100Ω |
| Bipolar – Standard Modulation Frequency | 20kHz |
| Bipolar – Standard Max Output Voltage | 700V |
| Bipolar – Standard Crest Factor | 1.9 |
Our Electrosurgical Unit MEU-705 is specifically designed to meet the demanding needs of veterinary surgical procedures, delivering precision, safety, and reliability in every use. It is ideal for a wide range of applications including soft tissue surgery, orthopedic procedures, and large or small animal surgeries.
Accessories Name Quantity Monopolar Foot-Switch 1 pc Bipolar Foot-Switch 1 pc Hand-Switch Pencil, Disposable 1 pc Patient Return Electrode Rods (10mm) with Cable, Reusable 1 pc Maryland Jaw Open and Laparoscopic Sealer, 5mm to 37cm 1 pc